Attic furnace will not heat? Call (817) 612-9107 or Book Online
Part of our Furnace Repair guide.
Quick answer
An attic furnace in Grand Prairie often fails on the first cold night after months of cooling, or because a float switch from the summer drain is still open. Check the thermostat, the filter, and one breaker reset. Do not open the burners in the attic. Boost Air repairs gas furnaces. Approved repairs include a $0 service fee. Same-day service is Monday through Friday.
Grand Prairie attic furnaces spend summer as a stand for the cooling coil. The gas heat may not run from April to November. The first cold night is the first test of the igniter, the flame sensor, and the inducer, and it is also when a float switch left over from an August condensate clog can still be open. No heat in that house is often a cooling-season leftover plus a part that sat still.
Boost Air And Plumbing repairs gas furnaces. We do not service boilers. Furnace repair is the service. HVAC service in Grand Prairie is the local page.
Smell gas and leave. Call the gas utility or 911 from outside. If a carbon monoxide alarm sounds, everyone out, then 911. Do not climb into the attic to investigate either one.
Do this from the hallway and the yard.
Wait one cycle. If it lights and stays lit, you are done. If it clicks and quits, stop resetting it.
We confirm the thermostat is calling, the door switch is closed, and a float is not the thing holding the gas valve off. Then the startup order: inducer, ignition, flame proof, blower. A sensor that lets the burners light and then drop out is a different part from an igniter that never glows. You should not have to guess which one from the hallway. We say which step stopped, and the price, before parts go in.
Approved repairs include a $0 service fee. Same-day service is Monday through Friday.
A limit that opens again after a new filter can be a duct problem, a dirty blower, or a furnace that is overheating for a worse reason. Repeated overheating is not fixed by bypassing the switch. Soot or a yellow flame means the furnace stays off. That can be a heat exchanger conversation and a free replacement estimate rather than another sensor.
Hours are Monday through Saturday, 8am to 7pm. Call (817) 612-9107 or book online.
Why would a Grand Prairie attic furnace fail on the first cold night? It sat through a long cooling season. The igniter, flame sensor, and inducer may not have run since spring. A float switch that protected the attic from a summer condensate clog can also hold the system off. The symptom is no heat. The cause may be leftover from cooling.
What is safe to check at the thermostat and the filter? Set Heat, fan AUTO, and a setpoint above the room. Replace a filter you cannot see through, and make sure the attic access panel or blower door is seated if you already had it open for the filter. Reset a breaker once. Do not go into the attic at night to open the burner compartment.
Can last summer's drain clog stop the heat? Yes. A float switch in the attic pan opens when water is high. It can break the call for heat the same way it broke the call for cooling in August. Clear a visible clog at the outdoor end of the PVC if you can reach it from the ground. If the pan is full near wiring, leave it.
When should I stop resetting it? After one or two tries, or immediately if you smell gas, hear a rollout, see soot, or the same code returns. Gas smell or a carbon monoxide alarm means leave and call from outside.
When is no heat a replacement quote? When the heat exchanger is cracked, the cabinet is rusted through, or a major part failed on a furnace around 15 years old. A sensor or igniter on a sound exchanger is often a repair. Approved repairs include a $0 service fee. Ask for a free replacement estimate if the numbers are close.
Call (817) 612-9107 or book online. We serve Arlington, Grand Prairie, and the surrounding North Texas communities.