Arlington (Main Office)
Boost Air And PlumbingArlington, TX
- 2313 Michigan Ct
Arlington, TX 76016 - (817) 612-9107
- Monday to Saturday: 8:00 AM to 7:00 PM

Boost Air Blog
Thermostat Says Heat but No Heat? Call (817) 612-9107 or Book Online
Part of our Furnace Repair guide.
Quick answer
Thermostat says heat but no heat in Arlington means the thermostat is in Heat and the house still does not warm up. Check the setpoint, the batteries, the breaker, the furnace switch, the filter, the blower door, and the manual gas valve. Write down any blink code you can read without leaving the door off. The ignitor, flame sensor, pressure switch, limit, board, and blower are a technician's checks. If you smell gas, leave and call the gas utility or 911 from outside.
Thermostat says heat but no heat is a common first cold night in Arlington. The screen says Heat. You raise the number. The rooms stay cold. Sometimes the furnace is silent. Sometimes the fan runs and the air never warms. Sometimes the burners light, die, and the thermostat never changes what it says.
Heat on the display is the mode, not a report that the burners are on. The call is the setpoint above the room temperature. If that call is real and the house still will not warm, the furnace is not finishing the sequence.
Furnace repair is the visit that finds which step stopped. HVAC service in Arlington is the local page. The Arlington shop is at 2313 Michigan Ct. The furnace is usually in a hall closet or the attic.
If you smell gas (a rotten egg odor), stop. Do not flip switches or use a phone inside. Leave the home and call the gas utility or 911 from outside. If a carbon monoxide alarm sounds, or anyone has a headache, nausea, or dizziness that eases outdoors, get everyone out and call 911. Carbon monoxide has no smell.
Set the system to Heat and the fan to AUTO. ON runs the blower whether or not the burners are lit, so the vents stay cold if the burners never light. That moving-air pattern is furnace blowing cold air in Grand Prairie.
Put the setpoint a few degrees above the room temperature on the screen and wait one cycle. The blower often starts 30 to 90 seconds after the burners light. Silence after several minutes is a failed start. A run of only a few minutes, repeating all evening, is furnace short cycling in Arlington.
If the house is cold and the thermostat reads 78, it will not call. A supply vent, a lamp, or sun on that wall does it, and so does a schedule or an away setpoint in the 60s. Hold a higher setpoint for one cycle.
Replace batteries if the thermostat takes them. A dim screen can still say Heat and fail to send a call. A screen that goes blank only when the furnace breaker is off was powered by the furnace. A screen that stays lit with the breaker off is on batteries, and the furnace has no power.
A thermostat that was just replaced is a wiring suspect. Pull it off the wall plate. A loose wire, or a wire on the wrong letter, leaves a normal screen and a silent furnace. Seat it on the letter it came from. If you do not know which letter, stop. Do not jumper terminals. The wrong pair can blow the fuse on the board.
The furnace switch sits on the cabinet or on a joist beside it, and it looks like a light switch. In a closet it gets flipped by habit. Turn it on and listen. The switch that lights the closet is not the test.
Then check the breaker. A gas furnace here is usually 120 volts. An electric furnace, or heat strips in an air handler, is often a double-pole 240-volt breaker. A tripped breaker often sits in the middle. Push it fully off, then on, once. If it trips again, leave it off. A furnace that keeps tripping the breaker is that fault. Do not install a larger breaker.
The blower door pushes a switch. Unlatched, many furnaces will not start. Seat the door until it clicks. Do not tape the switch.
Replace a filter you cannot see light through. Use the size printed on the cabinet. A thicker filter than the slot was built for can choke a furnace that looks freshly filtered. Open the supply vents, pull furniture off the returns, latch the door, and try one cycle. If heat comes back, you found it. If the burners light and die again, stop. Do not run the furnace with the filter out.
On the gas pipe at the furnace, the handle in line with the pipe is open. The handle across the pipe is closed. Turn it open only if you know someone closed it and you do not smell gas. Leave the knobs on the gas valve body alone. That valve stays shut until the board has proved draft and ignition. No gas smell does not mean the burners are being fed.
Read the status light through the door window, or unlatch the door, count the blinks, and match them to the chart printed inside that door. Write the pattern down, including any long pause, and latch the door. Do not remove the burner cover. Turn the furnace switch off for about 30 seconds and back on, once. If the same code returns, stop.
If the outdoor unit is what runs on a call for heat, the house is on a heat pump, and this gas sequence does not apply. An electric furnace has no gas valve to check.
The thermostat calls. The inducer runs. A pressure switch closes when that motor proves draft. The ignitor glows. The gas valve opens. The flame sensor has to prove flame. The blower starts after a delay. Warm air is the last step.
A cracked hot-surface ignitor will not glow, so the board keeps the gas valve closed. You hear the inducer, then nothing, and you should not smell gas. A coated flame sensor lets the burners light for a few seconds, then the valve closes, and the board locks out after a few tries. Cleaning helps only when the sensor is the fault. A yellow flame is not a cleaning job.
A pressure switch that will not close stops the sequence before the ignitor is powered. A blocked exhaust, a cracked or water-filled hose, a failed inducer, or a nest in the vent cap will do it. On a high-efficiency furnace a clogged condensate drain or an open float switch ends the call the same way. Do not jumper either switch.
The high limit opens when the heat exchanger is too hot, from the filter, closed vents, a dirty wheel, or a blower that is not moving air. A blower that will not run, or that will not stop, is its own fault. A rollout switch opens when flame leaves the burner box. Do not press its reset. Leave the furnace off.
The control board sends each of those calls. A board that never starts the inducer, the ignitor, or the blower looks like a broken wire between the wall and the furnace, which shows up after a thermostat swap. Replacing the board because the furnace is old, without a test, installs the wrong part.
You should hear which part failed, and the price, before it is replaced. An ignitor or a sensor, with a sound heat exchanger, is a repair. A cracked heat exchanger, a rusted cabinet, or a major failure on a furnace more than 15 years old is a time to hear a replacement price beside the repair. The U.S. Department of Energy's Energy Saver material lists that age as one reason to consider replacement, not as an expiration date. Ask for a free replacement estimate if the numbers are close. Financing as low as $99 a month is available on qualifying replacements. That figure is financing. The equipment price is in the written quote.
Leave the furnace off and call if any of these are true:
Write down the blink pattern, whether you hear the inducer, and whether any air moves. The service fee is $0 when you approve the repair. Same-day service is available Monday through Friday. Hours are Monday through Saturday, 8am to 7pm. Call (817) 612-9107 or book online. Say whether the furnace is silent, whether the fan runs, and what the light is doing.
Call (817) 612-9107 or book online. We serve Arlington, Grand Prairie, and the surrounding North Texas communities.
Visit our shops
Boost Air And Plumbing dispatches trucks from our Arlington main office and our Grand Prairie shop, covering Tarrant and Dallas counties with same-day HVAC and plumbing service. Call (817) 612-9107 for either location.
Arlington (Main Office)
Grand Prairie